The Effect of Particle Drag and Wall Absorption on Mass Transfer in Concentric Annulus Flows

Authors

  • B. Umadevi Department of Mathematics, JSS Academy of Technical Education, Bangalore –560060
  • Dinesh P.A. Department of Mathematics, MS Ramaiah Institute of Technology, Bangalore–560054
  • Indira R. Rao Department of Mathematics, Nitte Meenakshi Institute of Technology, Bangalore–560064
  • Vinay C.V. Department of Mathematics, JSS Academy of Technical Education, Bangalore –560060

DOI:

https://doi.org/10.12723/mjs.18.1

Abstract

The effects of the irreversible boundary reaction and the particle drag on mass transfer are studied analytically in concentric annulus flows. The solution of mathematical model, based on the generalized dispersion model brings out the mass transport following by the insertion of catheter on an artery in terms of the three effective transport coefficients, viz., the exchange, convection and diffusion coefficient. A general expression is derived which shows clearly the time dependent nature of the coefficients in the dispersive model. The complete time dependent expression for the exchange coefficient is obtained explicitly and independent of velocity distribution in the flow; however it does depend on the initial solute distribution. Because of the complexity of the problem only asymptotic large time evaluations are made for the convective and diffusion coefficients, but these are sufficient to give the physical insight into the nature of the problem of the effects of drag and absorption parameters. It is found that as absorption parameter increases exchange and convection coefficients will be enhanced, but diffusion coefficient will be reduced. After certain period of time exchange coefficient will be constant for different values annular gap. As the drag parameter increases convection and diffusion coefficients will be reduced. With the enhancement of catheter radius i.e., the annular gap will be reduced then the convection and diffusion coefficients will be decreased.

References

Back, L,H., Kwack, E.Y., Back, M.R., 1996., Flow rate-pressure drop relation in coronary angioplasty: Catheter obstruction effect. Journal of Biomechanical Engineering Transactions, ASME 118, 83-89.

Bloomingburg, G. F., Carta, G., 1994., Seperation of protein mixtures by continuous annular chromatography with step elution. The Chem Engn J.55, B19-B27.

Carta, G., Decarli, J. P., Byers, C. H., Sission, W. G., 1989.,Seperation of metals by continuous annular chromatography with step elution. Chem.Engng.Comm. 79,207-227.

Dash, R.K., Jayaraman, G., Mehta, K.N., 1996., Estimation of increased flow resistance in a narrow catheterized artery – a theoretical model. Journal of Biomechanics 29. 917-930.

DeGance, A.E., Johns, L.E, 1980., On the construction of dispersion approximations to the solution of the convective diffusion equation.AIChE.J 26, 411 – 419.

Sankarasubramanian, R., Gill, W.N., !973., Unsteady convective diffusion with interphase mass transfer.Proc. Roy. Soc. Lond. A. 333, 115 – 132.

A. Sarkar, G. Jayaraman., 1998., Correction to Flow Rate – Pressure Drop Relation in Coronary Angioplasty: Steady Streaming Effect. J. Biomechanics 31 ,781 – 791.

A. Sarkar, G. Jayaraman. 2001., Nonlinear analysis of oscillatory flow in the annulus of an elastic tube – application to catheterized artery. Phys. Fluids 13, 2901 – 2912.

Tsui, Y. T., Tremblay, B., 1984., On transient natural convection heat transfer in the annulus between concentric, horizontal cylinders with isothermal surfaces. Int. J. Heat Mass Transfer 27, 103 – 111.

Published

2021-08-26